Comb Portal: Version 1.7.3 or greater. MK II Lite Intercom firmware version: 1.18 or greater. TAP TAP Keypad firmware version: 2.0.9 or greater. |
Wire Diagram |
---|
Keypad ID Setup
Step | Description |
---|---|
1 | To determine if the keypad has the new version of firmware:
|
2 | Before a ID can be assigned to a keypad, the maintenance PIN must be configured on web site.
Note: Maintenance PIN "0000" will not be accepted by the keypad as a valid code. |
3 | To set a keypad ID:
For example *1234#5* or *1234#152 Note: The '*" button is used for codes between 1 and 99. Codes between 100 and 255 do not require the '*' button. |
4 | To confirm or check what the keypad ID is:
Note: The "Beep" count is limited to keypad ID's 1 to 10. |
|
|
Step | Description |
---|---|
1 | Before the relay pulse time can be set on the keypad, the maintenance PIN must be configured on web site.
Note: Maintenance PIN "0000" will not be accepted by the keypad as a valid code. |
2 | To set the relay pulse time:
Where xxx = 300 to 330. 300 = 0.5 seconds 301 = 1 second 302 = 2 seconds ... 330 = 30 seconds For example *1234#300 for 0.5 relay pulse time or *1234#315 for a 15 second relay pulse time. |
Feature | Description | Default setting |
---|---|---|
TAP Enable | To enable or disable the TAP functionality. | Disabled |
Maximum Taps | The number of TAP that can be requested by each unit in the complex. 0 to 250. | 0 |
Expire Type | On the hour: All Tap codes will expire at the specified hour. If the requested tap code is requested after the specified hour for that day, the code will expire the following day. Amount of hours: The Tap code will expire after x amount of hours from the time of the requested Tap code. Midnight: All Tap codes will expire at midnight. | On the hour |
Expire Amount | The amount of hours or the hour time for expiry. | 1 |
Tap channel A | Relay 1 to 5. Setting a relay will over-ride the relay defined in the TAP or PIN trigger settings. | None |
Tap channel B | Relay 1 to 5. Setting a relay will over-ride the relay defined in the TAPEX or PIN trigger settings. | None |
Append Msg to SMS | Allows the administrator to append a short message to the TAP SMS. | Blank |
Feature | Description | Default setting |
---|---|---|
TAPEx Enable | To enable or disable the TAPEX functionality. | Disabled |
Expire Type | On the hour: All Tap codes will expire at the specified hour. If the requested tap code is requested after the specified hour for that day, the code will expire the following day. Amount of hours: The Tap code will expire after x amount of hours from the time of the requested Tap code. Midnight: All Tap codes will expire at midnight. | On the hour |
Expire Amount | The amount of hours or the hour for expiry. | 1 |
Relay to send SMS | Relay 1 to 5. | None |
Relay to send SMS | Relay 1 to 5. | None |
Relay to send SMS | Relay 1 to 5. | None |
Relay to send SMS | Relay 1 to 5. | None |
Relay to send SMS | Relay 1 to 5. | None |
Display TAPX code | Allows the TAPEX code to be displayed on the LCD screen. | Disabled |
Append Msg to SMS | Allows the administrator to append a short message to the TAPEX SMS. | Blank |
Trigger Type | Relay | Time Table | Role |
---|---|---|---|
TAP | 1 | All times | Occupant |
TAPx | 2 | All times | Occupant |
TAP | 1 | All times | Owner |
Tapx | 2 | All times | Owner |
Before any triggers can be configured for TAP TAP keypad with an ID, the keypad must be first wired up to an intercom, configured and the intercom synchronized with the server. |
Trigger Type | Trigger Qualifier | Relays | Component setting: Channel A | Component setting: Channel B | Comments |
---|---|---|---|---|---|
PIN 1 PIN 2 TAP TAPEX | Not applicable | 1 to x | Will override the defined relay in the triggers setting. | Will override the defined relay in the triggers setting. | All trigger types will activate the relay as defined in the trigger unless channel A and B are defined. |
PIN 1 PIN 2 TAP TAPEX | Channel A | 1 to x and FRX | Not Applicable | Not Applicable | Each trigger type requires a trigger definition. |
PIN 1 PIN 2 TAP TAPEX | Channel B | 1 to x and FRX | Not Applicable | Not Applicable | Each trigger type requires a trigger definition. |
PIN 1 PIN 2 TAP TAPEX | Intercom | 1 to x | Not Applicable | Not Applicable | Each trigger type requires a trigger definition. |
PIN 1 PIN 2 TAP TAPEX | Peripheral | 1 to x and FRX | Not Applicable | Not Applicable | Each trigger type requires a trigger definition. |