MK II Lite – Release 1.21.1 – Release Notes
This release focuses on the following MK II PL faults:
No LCD display.
LCD display is toggling "Welcome" message but no response to key presses
No response to SMS commands
Requires a power cycle to get intercom to function again.
Review Headline Features below for more detail.
Please continue to provide objective feedback that we can act on to ensure you
receive better service and functionality as we strive to constantly enhance our
offering.
Beta Release date: 22/02/2021
Production Release date: 8/03/2021
Firmware Release Versions
WP8548: 3.5.16.1.21.1
WP7607-1: 3.6.12.0.1.21.1
Release Action
Release Priority | Release Action |
---|---|
Medium | As required |
Release Headline Features
Ticket Number | Description |
MKIIPL-347 | Increase timeout between unit select and selecting Positions 1,2,3 to 7 seconds as per MK II BB devices - The timeout between selecting a unit and selecting a person in the unit was increased from 2 seconds to 7 seconds to match the current timeout on the MK II BB devices. |
MKIIPL-351 | Persist logging to files system & create a setting on portal for enabling debug mode on a MKII Lite board - Create a new token to enable/disable debug mode on MKII Lite
|
MKIIPL-352 | Disable HSIC on the MKII Board on the Birth Process - |
MKIIPL-353 | Fix the watchdog handling operation - Add 30s timer to watchdog fed every second from OBR thread under normal operation instead of a infinite loop on graceful restart [0004/7633/sms/gsm fail], abort after 60s. Set watchdog timer as a system default of 300 [30s] |
Internal Cleanup | Fix an log message error near "lastreg" - Fix SQL query for looking up ICCID. |
© 2018 Comb Communications. All Rights Reserverd.